Modular distribution system Thermax

• for wall-mounted boilers

 

The modular distribution manifold system Thermax is a preassembled group of fittings for heating circuits.
It consists of a Thermax distribution manifold, two Thermax heating circuit modules and a design insulation with optimised function.
Thermax can be mounted directly to the wall or with distance pieces at a distance of 100 mm to the wall. This means that additional flow lines to the boiler can be installed behind the Thermax.
Complete hydraulic separation between the connected circuits and the boiler is possible.
The adjustable bypass (0 - 100%) of the Thermax manifold guarantees forced circulation in the boiler when the bypass is open.

Two different heating circuits to select from:

  • Unmixed heating circuit K31 - for modulating temperature heating systems
  • Heating circuit K32 - with 3-way mixing valve - for heating systems controlled by a
    mixing valve

Different pumps to select from:

  • Wilo Star-RS 15/4, Wilo Star-RS 15/6, Wilo Star-E 15/1-5
    Grundfos UPS 15-40, Grundfos UPS 15-60, Grundfos UPE 15-60
  • All necessary fittings included
  • All installation positions possible
  • Pumps can be isolated
  • Ball valves in the flow and the return
  • Immersion sleeves integrated in the ball valves to install flow and return temperature
    sensors
  • Mixing valve with electric actuator
    The flow is on the right; it can be simply changed on site
The Thermax system has been designed for applications with two different temperature levels. An application
example: it can be connected to a consumer with a high flow temperature (such as a radiator) and a consumer
with a low flow temperature (such as a radiant floor heating).
Thermax controller
The Thermax controller can be used to control heating systems with two heating circuits with motorised
mixing valves. The boiler temperature is controlled dependent on both heating circuits, while the difference
between the boiler temperature and the flow temperatures of the heating circuits can be adjusted between 5
and 20 K. The controller is also suitable for systems with two-stage-burners or two boilers and is able to actuate
a charge pump. Both heating circuits have separate time programs and can be controlled separately by two analogue or digital remote controls.
 

More product details on our downloadsite.