BoostBloC®
Heat
pump
post-heating
BoostBloC® DN 25+
PAW BoostBloC® post-heating module - for a high heating and hot water convenience
Manufacturer:
Operating data
Max. operating temperature:
75 °C
Max. operating pressure:
3 bar
Kvs value:
8,5
Fluid:
Heating water
Minimum volume flow rate (during heating):
500 l/h
Nominal capacity:
0.8 l
Residual head (at 2000 l/h):
60,8 kPa
Equipment
Shut-off valves:
Ball valves with handle
Sensors:
2 x Pt1000
Safety valve:
3 bar
Pump designation:
Grundfos UPM4L 25-75
Dimensions
Height:
711 mm
Width:
410 mm
Nominal diameter:
DN 25 (1")
Installation length:
660 mm
Installation depth:
213 mm
Centre distance:
180 mm
Flow / return consumer:
1½" int. thread
Flow / return heat pump:
1½" int. thread
Materials
Valves and fittings:
brass,copper
Gaskets:
EPDM / Novapress Universal
Cover:
steel, galvanised
Electrical data (heating/actuators)
Protection class:
I
Protection class:
IP 20
Torque actuator:
5 Nm, 2-Punkt-Ansteuerung
Heating cartridge - control:
External control required,3x relay (230 VAC, 50 Hz, < 5 VA)
Heating cartridge - electrical connection:
400 V / 3N / 50 Hz
Heating cartridge - cable cross-section:
2,5 - 6 mm²
Heating cartridge - nominal output level 1:
P 1 = 3000 W
Heating cartridge - nominal output level 2:
P 2 = 3000 W
Heating cartridge - nominal output level 3:
P 3 = 3000 W
Pump - feature:
PWM interface with feedback signal for volume flow rate determination
Pump - electrical connection:
230 VAC/50 Hz, 0,66 A
STB - Switch-off temperature:
95 °C +/- 3K
STB - Voltage:
400 V
Actuator - data:
13 s/90°, 60 % EDmax
Actuator - electrical connection:
230 V, 50 Hz, <5 VA
Actuator - protection category:
IP 42
Actuator - protection class:
II
Heat pumps provide sufficient energy at different temperature conditions in order to offer a high heating and hot water convenience. For the case
that this is not sufficient, the PAW BoostBloC® is activated and provides additional thermal energy via an instant water heater.
The post-heating module is a preassembled group of fittings for heat pump applications.All electronic components such as the instant water heater or the pump
can be isolated by means of the ball valves.They can thus be maintained easily without draining the heating or charging circuit system.
The PAW BoostBloC® is mounted directly at the wall and serves to post-heat a storage tank.The system can be extended by further components as a domestic hot water module or a heating distribution manifold.
The station requires an additional controller and is normally actuated by the heat pump controller.It is connected to the external controller via
the enclosed small distribution manifold.Via a post-heating request (230 V) of the controller, the power contactor is actuated, which is integrated in the small distribution manifold.In the type with contactor,
there is no power control; only the one preset power (8.8 kW) of the tubular heating element is actuated.
Depending on the controller and connection type, the pump can be connected simultaneously to the heat generator or separately.
For an independent valve control of the integrated flow stratification, a continuous phase as well as a further switch contact are required.
that this is not sufficient, the PAW BoostBloC® is activated and provides additional thermal energy via an instant water heater.
The post-heating module is a preassembled group of fittings for heat pump applications.All electronic components such as the instant water heater or the pump
can be isolated by means of the ball valves.They can thus be maintained easily without draining the heating or charging circuit system.
The PAW BoostBloC® is mounted directly at the wall and serves to post-heat a storage tank.The system can be extended by further components as a domestic hot water module or a heating distribution manifold.
The station requires an additional controller and is normally actuated by the heat pump controller.It is connected to the external controller via
the enclosed small distribution manifold.Via a post-heating request (230 V) of the controller, the power contactor is actuated, which is integrated in the small distribution manifold.In the type with contactor,
there is no power control; only the one preset power (8.8 kW) of the tubular heating element is actuated.
Depending on the controller and connection type, the pump can be connected simultaneously to the heat generator or separately.
For an independent valve control of the integrated flow stratification, a continuous phase as well as a further switch contact are required.
Safety instructions The installation and commissioning as well as the connection of electrical components require technical knowledge commensurate with a recognised vocational qualification as a fitter for plumbing, heating and air conditioning technology, or a profession requiring a comparable level of knowledge [specialist]. The following must be observed during installation and commissioning: - relevant local and national regulations - accident prevention regulations of the professional association - instructions and safety instructions mentioned in these instructions.