Search results for: '145 440 80'
Did you mean 15 40 80?
-
Return flow temperature maintenance with actuator - DN 20 (¾")Return flow temperature maintenance - DN 20 (¾")
with actuator
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with actuator - DN 25 (1")Return flow temperature maintenance - DN 25 (1")
with actuator
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with actuator - DN 32 (1¼")Return flow temperature maintenance - DN 32 (1¼")
with actuator
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with actuator - DN 40 (1½")Return flow temperature maintenance - DN 40 (1½")
with actuator
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with actuator - DN 50 (2")Return flow temperature maintenance - DN 50 (2")
with actuator
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW actuator SR10due to the removable scale it is suited for flow on the right or left side,
easy assembly and disassembly thanks to the smart PAW snap-in mechanism,
with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve,
for weather-compensated control, change-over switch for manual / automatic operation
Technical data
Electrical connection: 230 V / 50 Hz
Input power: 3.5 W
Torque: 10 Nm
Setting time for 90°: 140 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW actuator SR10 for DN 40due to the removable scale it is suited for flow on the right or left side, easy assembly and disassembly thanks to the smart PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, change-over switch for manual / automatic operation
Technical data
Electrical connection: 230 V / 50 Hz
Input power: 3.5 W
Torque: 10 Nm
Setting time for 90°: 140 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW actuator SR10 for DN 50due to the removable scale it is suited for flow on the right or left side, easy assembly and disassembly thanks to the smart PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, change-over switch for manual / automatic operation
Technical data
Electrical connection: 230 V / 50 Hz
Input power: 3.5 W
Torque: 10 Nm
Setting time for 90°: 140 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW actuator SR5Change-over switch for manual / automatic operation,
easy assembly and disassembly thanks to the smart PAW snap-in mechanism,
with 1.5 m cable and mounting set for snap-in assembly on the PAW mixing valve,
for weather-compensated control,
due to the removable scale it is suited for the flow on the right or left side
Technical data
Electrical connection: 230 V / 50 Hz
Input power: 2.5 W
Torque: 5 Nm
Setting time for 90°: 140 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
System separation DN 25 (1") for HeatBloC®sFunction:
Separation of the boiler circuit and the consumer circuit
Field of application:
for radiant panel heating systems with plastic pipes for the protection of new boilers in older heating installations
Recommended application range:
Min. residual head: 1.5 m
Temperature difference primary: 60-50 °C
Temperature difference secondary: 35-45 °C
Range of performance:
depending on the pump of the heating circuit used and the amount of plates of the heat exchanger
16 plates: up to 20 kW, 10 K up to 1720 l/h
30 plates: up to 23 kW, 10 K up to 2010 l/h
40 plates: up to 25 kW, 10 K up to 2150 l/h Learn MoreOur offer is exclusively aimed at corporate clients.