Search results for: 'Pump head'
- Related search terms
- head
- head ext
- head extr
- head external
- header
-
System separation DN 25 (1") for HeatBloC®sFunction:
Separation of the boiler circuit and the consumer circuit
Field of application:
for radiant panel heating systems with plastic pipes for the protection of new boilers in older heating installations
Recommended application range:
Min. residual head: 1.5 m
Temperature difference primary: 60-50 °C
Temperature difference secondary: 35-45 °C
Range of performance:
depending on the pump of the heating circuit used and the amount of plates of the heat exchanger
16 plates: up to 20 kW, 10 K up to 1720 l/h
30 plates: up to 23 kW, 10 K up to 2010 l/h
40 plates: up to 25 kW, 10 K up to 2150 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K36E DN 32 (1¼")Boiler charging set with integrated overflow valve
Field of application: Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems Recommended application range: up to 60 kW; 20 K up to 2600 l/h
390343x: Opening temperature 45 °C
390373x: Opening temperature 60 °C
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 32 (1¼")direct / unmixed
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 65 kW; 20 K up to 2800 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 50 (2")direct / unmixed
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 250 kW; 20 K up to 10800 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 40 (1½")direct / unmixed
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 150 kW; 20 K up to 6500 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 20 (¾")direct / unmixed
Application range: for boiler charging, for modulating temperature heating
Recommended application range: up to 30 kW; 20 K up to 1300 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 25 (1")direct / unmixed
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 50 kW; 20 K up to 2150 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K36E DN 25 (1")Boiler charging set with integrated overflow valve
Field of application: Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 40 kW; 20 K up to 1725 l/h
360343x: Opening temperature 45 °C
360373x: Opening temperature 60 °C
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K36 DN 20 (¾")Boiler charging set with thermal control valve
Field of application: Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 10 kW; 10 K up to 860 l/h
Opening temperature 45 °C (item no. 320353xx)
Opening temperature 60 °C (item no. 320363xx)
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33 DN 25 (1")Constant value control circuit, thermostatic
Field of application: for radiant floor heating from 3.5 kW, for low-temperature heating systems
Recommended application range: up to 10 kW; 10 K up to 860 l/h↲
Learn MoreOur offer is exclusively aimed at corporate clients.