Search results for: 'can au so pump'
Did you mean can au so pompe?
- Did you mean
- cap au so pump
- can au so pomp
- Related search terms
- can
- can 4 von
- can au so paw
- can 4 ventil
- can 4 voi
-
HeatBloC® K31 DN 25 (1")direkt / ungemischt
Anwendungsbereich: für Boilerladung, für gleitenden Heizbetrieb
Empfohlener Einsatzbereich: bis 50 kW; 20 K bis 2150 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMini TW up to 36 m²Field of application: for charging buffer storage tanks
Application range: up to 36 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMini HZ up to 36 m²Field of application: for charging buffer storage tanks
Application range: up to 36 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMidi HZ up to 60 m²Field of application: for charging buffer storage tanks
Application range: up to 60 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMaxi HZ up to 100 m²Field of application: for charging buffer storage tanks
Application range: up to 100 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMega HZ up to 200 m²Field of application: for charging buffer storage tanks
Application range: up to 200 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMega-Kaskade HZ up to 400 m²Field of application: for charging buffer storage tanks
Application range: up to 400 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® midi Basic RücklaufstationEinsatzbereich:
Low-Flow (= 0,25 l/Minute je m² Kollektorfläche), bis 60 m² Kollektorfläche
High-Flow (= 0,5 l/Minute je m² Kollektorfläche), bis 40 m² Kollektorfläche
Bitte beachten Sie:
Damit eine problemlose Funktion sichergestellt werden kann, ist eine hydraulische Auslegung/Überprüfung der Solaranlage erforderlich.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Hydraulische Weiche DN 20 (¾")Hydraulische Weichen werden eingesetzt, wenn in einer Anlage gleichzeitig ein oder mehrere Wärmeerzeuger-/Primärkreise mit eigener Pumpe und ein oder mehrere Verbraucher-/Sekundärkreise mit Verteilerpumpe vorhanden sind.
Die hydraulische Weiche bildet eine hydraulische Entkopplung der angeschlossenen Kreise.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Hydraulische Weiche DN 25 (1")Hydraulische Weichen werden eingesetzt, wenn in einer Anlage gleichzeitig ein oder mehrere Wärmeerzeuger-/Primärkreise mit eigener Pumpe und ein oder mehrere Verbraucher-/Sekundärkreise mit Verteilerpumpe vorhanden sind.
Die hydraulische Weiche bildet eine hydraulische Entkopplung der angeschlossenen Kreise.
Learn MoreOur offer is exclusively aimed at corporate clients.