Search results for: 'contr au so pk'
Did you mean control au so pk?
- Did you mean
- control au so pk
- centr au so pk
- Related search terms
- contr au so plat
- contr au so paw
- contr au so plate
- contr au so point
- contr au so part
-
Controller Alpha BasisConnection unit for single room controls of heating and cooling systems in combination with surface temperature regulation.
The power supply of the components is provided directly via the controller; minimised wiring effort.
Controller Alpha Basis STD Plus: Designated for the connection of up to 6 room operating units and up to 15 actuators with 230 V~ operating voltage.
Controller Alpha Basis Comfort: Designated for the connection of up to 10 room operating units and up to 18 actuators with 230 V~ operating voltage.
Features:
• Signal input for temperature limitation or dew point sensor
• Connection for an external time switch
• Change Over connection for switching between heating and cooling
• Controller Alpha Basis STD Plus: control of the pump
• Controller Alpha Basis Comfort: extended control of boiler and pump, after-run time adjustable
• Direction of operation of the actuators "zero current closed" (NC); without pump control, also "zero current open" (NO) possible
Scope of delivery:
Wall bracket with mounting rail for an easy and direct installation in the wall-mounted or flush-mounted cupboard Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with thermal control valve (45 °C) - DN 20 (¾")Return flow temperature maintenance - DN 20 (¾")
with thermal control valve (45 °C)
Opening temperature: 45 °C
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with thermal control valve (60 °C) - DN 20 (¾")Return flow temperature maintenance - DN 20 (¾")
with thermal control valve
Opening temperature: 60 °C
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with thermal control valve (45 °C) - DN 25 (1")Return flow temperature maintenance RHT - DN 25 (1")
with thermal control valve
Opening temperature: 45 °C
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with thermal control valve (60 °C) - DN 25 (1")Return flow temperature maintenance RHT - DN 25 (1") with thermal control valve
Opening temperature: 60 °C
Field of application: for heating systems with return flow temperature maintenance for solid fuel boilers, wood-fired and stove heating systems Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with thermal control valve (45 °C) - DN 25 (1") - 32 (1¼")Return flow temperature maintenance RHT - DN 25 (1") - 32 (1¼")
with thermal control valve
Opening temperature: 45 °C
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with thermal control valve (60 °C) - DN 25 (1") - 32 (1¼")Return flow temperature maintenance RHT - DN 25 (1") - 32 (1¼")
with thermal control valve
Opening temperature: 60 °C
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Room control unitZur Inbetriebnahme der Station und Einstellung der Warmwasser-Solltemperatur. Eine Raumbedieneinheit ist bereits im Lieferumfang der Stationen enthalten. Ergänzung von bis zu 4 weiteren Raumbedieneinheiten je Station (Regler) möglich. Learn MoreOur offer is exclusively aimed at corporate clients.
-
MB3.10Communication module to integrate PAW systems with domestic hot water controllers FC3.10 into superior systems with Modbus RTU interface.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Thermoelectric actuator NC, 230 VThermoelectric actuator NC, 230 V
1288601101: with connecting adapter for IMI valves or Frese differential pressure controller.
1288601102: with connecting adapter for PAW floor distribution manifold valves.
1288601103: with connecting adapter for PAW injection-type circuit.
The actuator is controlled by a 230 V standard room temperature controller with a 2-point output or a pulse width modulation. Learn MoreOur offer is exclusively aimed at corporate clients.