SolexMega TW up to 200 m²Field of application: for charging buffer storage tanks
Application range: up to 200 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMega HZ up to 200 m²Field of application: for charging buffer storage tanks
Application range: up to 200 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
Overflow setOverflow valve with scale, bypass pipe, elbow gland, completely self-sealing.
Centre distance A = length, see table
For larger distances, a copper pipe 22 in the necessary length must be installed on site.
2850 and 2851: with screw connection 2 x ½" external thread
2853: with screw connection 2 x ¾", flat-sealing, suitable for foreign products Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® midi Basic, 3-lineApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 60 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 40 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33 DN 25 (1")Constant value control circuit, thermostatic
Field of application: for radiant floor heating from 3.5 kW, for low-temperature heating systems
Recommended application range: up to 10 kW; 10 K up to 860 l/h↲
Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® maxi BasicApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 125 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 80 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33R DN 25 (1")Constant value control circuit, electronic
Field of application: for thermally controlled radiant heating, for low-temperature heating used as a return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range:
up to 22.5 kW*; (radiant heating, Delta T = 10 K)
up to 45 kW* (return flow temperature maintenance, Delta T = 20 K),
10 / 20 K up to 1940 l/h ↲ Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33R DN 32 (1¼")Constant value control circuit, electronical
Field of application: for thermally controlled radiant heating, for low-temperature heating used as a return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 32 kW; (radiant heating, Delta T = 10 K)
up to 64 kW (return flow temperature maintenance, Delta T = 20 K), 10 / 20 K up to 2760 l/h ↲
Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® midi Basic return stationApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 60 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 40 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.