Search results for: 'heat pipe'
- Related search terms
- Heat
- heat ext
- heat extern
- heat extens
- heat exchanger
-
Extension pipe set DN 25For installation of three K35 HeatBloC®s the extension pipe set DN 25 is additionally required to extend 36092KS2.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Pressure-dependent heat retentionPressure-depending heat retaining for the installation in a HomeBloC® for a higher water convenience during summer operation
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Fitting for heat flowmeter DN 20- for HeatBloC®s DN 20
- for heat flowmeters with the dimensions ¾" external thread x 110 mm
- to be mounted above the insulation
Scope of delivery:
- Thermo ball valve
- Screw-in fittings
- Union nuts
- Adapter pipe
- Flange fitting
- T-piece with counter nut and immersion sleeve
- Seals
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Fitting for heat flowmeter DN 25 for unmixed HeatBloC®s- for unmixed HeatBloC®s DN 25
- for heat flowmeters with the dimensions ¾" x 110 mm and 1" x 130 mm
Scope of delivery:
- Pump ball valve with check valve, can be opened (200 mm wc)
- Screw-in fittings
- Union nuts
- Adapter pipe
- Flange fitting
- Reducers for immersion sensor (¼" ext. thread, self-sealing x M10 x 1" int. thread and ¼" ext. thread, self-sealing x M12 x 1.5" ext. thread)
- Seals
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Fitting for heat flowmeter DN 32 for unmixed HeatBloC®s- for unmixed HeatBloC®s DN 32
- for heat flowmeters with the dimensions ¾" x 110 mm and 1" x 130 mm
Scope of delivery:
- Pump ball valve with check valve, can be opened (200 mm wc)
- Screw-in fittings, flat sealing
- Union nut
- Adapter pipe
- Reducers for immersion sensor (¼" ext. thread, self-sealing x M10 x 1" int. thread and ¼" ext. thread, self-sealing x M12 x 1.5" ext. thread)
- Seals
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Fitting for heat flowmeter DN 25 for mixed HeatBloC®s- for HeatBloC®s DN 25 with 3-way or 4-wax mixing valve
- for heat flowmeters with the dimensions ¾" ext. thread x 110 mm
Scope of delivery:
- Screw-in fittings
- Union nuts
- Adapter pipe
- Reducers for immersion sensor (¼" ext. thread, self-sealing x M10 x 1" int. thread and ¼" ext. thread, self-sealing x M12 x 1.5" ext. thread)
- Non-return valve for mixing valve return
- Seals
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Fitting for heat flowmeter DN 32 for mixed HeatBloC®s- for HeatBloC®s DN 32 with 3-way or 4-wax mixing valve
- for heat flowmeters with the dimensions 1" ext. thread x 130 mm
Scope of delivery:
- Screw-in fittings flat sealing
- Adapter pipe
- Reducers for immersion sensor (¼" ext. thread, self-sealing x M10 x 1" int. thread and ¼" ext. thread, self-sealing x M12 x 1.5" ext. thread)
- Non-return valve for mixing valve return
- Seals
Learn MoreOur offer is exclusively aimed at corporate clients.
-
System separation DN 25 (1") for HeatBloC®sFunction:
Separation of the boiler circuit and the consumer circuit
Field of application:
for radiant panel heating systems with plastic pipes for the protection of new boilers in older heating installations
Recommended application range:
Min. residual head: 1.5 m
Temperature difference primary: 60-50 °C
Temperature difference secondary: 35-45 °C
Range of performance:
depending on the pump of the heating circuit used and the amount of plates of the heat exchanger
16 plates: up to 20 kW, 10 K up to 1720 l/h
30 plates: up to 23 kW, 10 K up to 2010 l/h
40 plates: up to 25 kW, 10 K up to 2150 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMega-Kaskade TW up to 400 m²Field of application: for charging buffer storage tanks
Application range: up to 400 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® midi PremiumApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 60 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 40 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.