Connection:
5234: ⅜" ext. thread
5235: ½" ext. thread Learn MoreOur offer is exclusively aimed at corporate clients.
-
3-way zone valveCan be used in solar and heating installations, to switch between different zones or to connect and disconnect different parts of the system.
The actuator is equipped with a relay which is actuated by a 2-point signal, if need be it can also be manually operated.
The 3-way zone valve can be operated in both directions. Learn MoreOur offer is exclusively aimed at corporate clients.
-
2-way zone valveCan be used in solar and heating installations as a zone valve, which means that single parts of the system can be connected or disconnected.
The actuator is equipped with a relay which is actuated by a 2-point signal, if need be it can also be manually operated.
The 2-way zone valve can be operated in both directions. Learn MoreOur offer is exclusively aimed at corporate clients.
-
3-way valve PV3Can be used in solar and heating installations, to switch between different zones or to connect and disconnect different parts of the system. The actuator is equipped with a relay which is actuated by a 2-point signal, if needed, it can also be manually operated. The 3-way valve PV3 can be operated in both directions.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
System separation DN 25 (1") for HeatBloC®sFunction:
Separation of the boiler circuit and the consumer circuit
Field of application:
for radiant panel heating systems with plastic pipes for the protection of new boilers in older heating installations
Recommended application range:
Min. residual head: 1.5 m
Temperature difference primary: 60-50 °C
Temperature difference secondary: 35-45 °C
Range of performance:
depending on the pump of the heating circuit used and the amount of plates of the heat exchanger
16 plates: up to 20 kW, 10 K up to 1720 l/h
30 plates: up to 23 kW, 10 K up to 2010 l/h
40 plates: up to 25 kW, 10 K up to 2150 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
3-way zone valve DN 20for switching between single storage tanks,
DN 20, ¾" int. thread,
setting time for 90°: 18 sec.,
Kvs value = 7 Learn MoreOur offer is exclusively aimed at corporate clients.
-
Overflow setOverflow valve with scale, bypass pipe, elbow gland, completely self-sealing.
Centre distance A = length, see table
For larger distances, a copper pipe 22 in the necessary length must be installed on site.
2850 and 2851: with screw connection 2 x ½" external thread
2853: with screw connection 2 x ¾", flat-sealing, suitable for foreign products Learn MoreOur offer is exclusively aimed at corporate clients.
-
Overflow set for HeatBloC®s DN 20with self-sealing counter-T-pieces and elbow gland, adjustment range 1-6 m wc, suitable for HeatBloC®
Learn MoreOur offer is exclusively aimed at corporate clients.
-
2-way zone valve DN 20for connecting and disconnecting single storage tanks,
DN 20, ¾" int. thread,
setting time for 90°: 30 sec. Learn MoreOur offer is exclusively aimed at corporate clients.
-
2-way zone valve DN 25/32for connecting and disconnecting single storage tanks,
DN 25, 1" int. thread, setting time for 90°: 30 sec.
DN 32, 1¼" internal thread, setting time 90°: 30 s Learn MoreOur offer is exclusively aimed at corporate clients.