SolexMega-Kaskade TW up to 400 m²Field of application: for charging buffer storage tanks
Application range: up to 400 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
Reducer set DN 32 - DN 25for the installalation of DN 25 HeatBloC®s on DN 32 distribution manifolds,
adapter set 2" external thread, flat-sealing with nut on 1½" internal thread, flat-sealing, made of brass, with gaskets, 2 types
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Reducer set DN 25 - DN 20for installation of HeatBloC®s DN 20 on modular distribution manifolds DN 25,
adapter set 1½" external thread, flat-sealing with nut on ¾" PAW flange,
reduction of the centre distance from 125 mm to 90 mm,
distance pipe 1" internal thread x 1" external thread, flat sealing, brass, with sealing.
The required union nuts 1" internal thread are part of the scope of delivery of the HeatBloC®s.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Connection set DN 20Consisting of 2 adapter pieces with 1" nut and ¾" internal thread for connecting pipes with ¾" external thread under modular distribution manifolds DN 20 (¾")
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Thermax - DN 20Field of application: for wall-mounted boilers
Recommended application range:
K31: up to 23 kW; 20 K up to 1000 l/h
K32: up to 19 kW; 20 K up to 820 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
2-way zone valveCan be used in solar and heating installations as a zone valve, which means that single parts of the system can be connected or disconnected.
The actuator is equipped with a relay which is actuated by a 2-point signal, if need be it can also be manually operated.
The 2-way zone valve can be operated in both directions. Learn MoreOur offer is exclusively aimed at corporate clients.
-
2-way zone valve DN 25/32for connecting and disconnecting single storage tanks,
DN 25, 1" int. thread, setting time for 90°: 30 sec.
DN 32, 1¼" internal thread, setting time 90°: 30 s Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 50 (2")direct / unmixed
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 250 kW; 20 K up to 10800 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 40 (1½")direct / unmixed
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 150 kW; 20 K up to 6500 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K32 DN 50 (2")3-way mixing valve
Field of application: for heating systems controlled by a mixing valve
Recommended application range: up to 230 kW; 20 K up to 9980 l/h
Flow and return line can be changed on site, the mixing valve can be easily adapted.
The HeatBloC® can be delivered with flow on the left against additional charge.
Learn MoreOur offer is exclusively aimed at corporate clients.