SolexMini HZ up to 36 m²Field of application: for charging buffer storage tanks
Application range: up to 36 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMidi HZ up to 60 m²Field of application: for charging buffer storage tanks
Application range: up to 60 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMaxi HZ up to 100 m²Field of application: for charging buffer storage tanks
Application range: up to 100 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMega HZ up to 200 m²Field of application: for charging buffer storage tanks
Application range: up to 200 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMega-Kaskade HZ up to 400 m²Field of application: for charging buffer storage tanks
Application range: up to 400 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMini TW up to 36 m²Field of application: for charging buffer storage tanks
Application range: up to 36 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33R DN 25 (1")Konstant-Temperatur-Regelkreis, elektronisch
Anwendungsbereich: für thermisch geregelte Flächenheizungen, für Niedertemperaturheizungen, als Rücklauf-Hochhaltung für Festbrennstoffkessel sowie Holzfeuerungsanlagen und Kamin-/Ofenheizung
Empfohlener Einsatzbereich: bis 22,5 kW* (Flächenheizung, ΔT = 10 K)
bis 45 kW* (Rücklauf-Hochhaltung, ΔT = 20 K); 10 / 20 K bis 1940 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K35 DN 25 (1")3-Temperaturen-Mischer
Anwendungsbereich: Heizungsanlagen mit Pufferspeicher und solarer Heizungsunterstützung, Regelung von Fußboden- und Flächenheizungen
Empfohlener Einsatzbereich: bis 32,5 kW; 20 K bis 1400 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33R DN 32 (1¼")Konstant-Temperatur-Regelkreis, elektronisch
Anwendungsbereich: für thermisch geregelte Flächenheizungen, für Niedertemperaturheizungen, als Rücklauf-Hochhaltung für Festbrennstoffkessel sowie Holzfeuerungsanlagen und Kamin-/Ofenheizung
Empfohlener Einsatzbereich: bis 32 kW (Flächenheizung, ΔT = 10 K)
bis 64 kW (Rücklauf-Hochhaltung, ΔT = 20 K); 10 / 20 K bis 2760 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMaxi TW bis 100 m²Anwendungsbereich: zur Beladung von Trinkwasserspeichern
Einsatzbereich: bis 100 m² Kollektorfläche
inkl. Wärmemengenzählung gemäß BAFA-Förderrichtlinie für thermische Solaranlagen
Die Station ist CE konform nach DIN EN 60335.