Search results for: 'vor 2160'
Did you mean vor 2016?
-
Stainless-steel corrugated hose SolarflexIdeal for the roof part leading to the collector. Learn More
Our offer is exclusively aimed at corporate clients.
-
Reducer set DN 40 - DN 32Reducer flanges made of brass for the assembly of a pump DN 32* in HeatBloC®s DN 40 or for connection of a single HeatBloC® DN 32 on a distribution manifold DN 40.
One side flange DN 40 - PN 6, other side flange for 2" union nut, flat sealing.
Reduction of the centre distance from 160 mm to 125 mm, installation height = 35 mm.
*For the installation of a DN 32 pump 2x nut and seals are required additionally (2x N00121).
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Reducer set DN 50 - DN 402 reducing flanges made of zinced steel for connecting a DN 40 HeatBloC® on a DN 50 modular distribution manifold. For the assembly of a DN 40 pump, installation length 250 mm, in a DN 50 HeatBloC®.
One side DN 50 flange (PN 6), other side DN 40 flange (PN 6). Reduction of the centre distance from 180 mm to 160 mm, with seals and screws, installation height = 13 mm
Use only with slip-on flanges!
Learn MoreOur offer is exclusively aimed at corporate clients.
-
System separation DN 25 (1") for HeatBloC®sFunction:
Separation of the boiler circuit and the consumer circuit
Field of application:
for radiant panel heating systems with plastic pipes for the protection of new boilers in older heating installations
Recommended application range:
Min. residual head: 1.5 m
Temperature difference primary: 60-50 °C
Temperature difference secondary: 35-45 °C
Range of performance:
depending on the pump of the heating circuit used and the amount of plates of the heat exchanger
16 plates: up to 20 kW, 10 K up to 1720 l/h
30 plates: up to 23 kW, 10 K up to 2010 l/h
40 plates: up to 25 kW, 10 K up to 2150 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
Flush-mounted cupboard stationConsisting of:
• Built-in body made of zinc-galvanised sheet steel, with height-adjustable feet
• Plinth panel and cover frame made of zinc-galvanised sheet steel, white powder-coated (RAL9016),
• Door to hang in, with rotary lock, made of zinc-galvanised sheet steel, white powder-coated (RAL9016), with ventilation slots
Other colours or printing on request,
Lock interchangeable Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® midi Basic, 3-lineApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 60 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 40 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® maxi BasicApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 125 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 80 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® midi Basic return stationApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 60 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 40 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® maxi Basic return stationApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 125 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 80 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.