FriwaMidi up to 60 l/min, FC3.10

Domestic hot water preparation operating on the principle of a flow-type water heater
Withdrawal capacity: 2-60 l/min

Circulation: optional
SKU
64055XXX
Prices are only visible for registered users.

Our offer is exclusively aimed at corporate clients.

Manufacturer:
PAW GmbH & Co. KG
Böcklerstr. 11 31789 Hameln
Germany
info@paw.eu
Operating data
Max. operating pressure primary: 6 bar
Max. operating pressure secondary: 10 bar
Max. operating temperature primary: 90 °C
Max. operating temperature secondary: 85 °C
Max. flow rate: 60 l/min
Transmission performance: 209 kW
Min. flow rate: 2 l/min
Equipment
Controller: FC3.10
Check valves: primary: 2 x 190 mm wc
Shut-off valves: Ball valves and piston valves
Sensors: primary: 1 x Pt1000 / secondary: 2 x Pt1000 / 1x flow rate sensor
Heat exchanger: XB37H, 40 plates, Cu/StS
Flow rate sensor: VTY20; 1 - 60 l/min
Circulation: optional
Flow meter: 1 - 60 l/min
Opening pressure check valve: 2x 190 mm wc
Dimensions
Height: 795 mm
Width: 602 mm
Nominal diameter: DN 20 (¾")
Depth: 298 mm
Installation length: 757 mm
Connection primary: G 1½" AG
Connection secondary: G 1" ext. thread
Connection circulation line: G 1" ext. thread
Centre distance primary: 120 mm
Centre distance secondary: 100 mm
Materials
Valves and fittings: brass
Gaskets: EPDM / Novapress Universal
Insulation: EPP
Piping: stainless steel
Check valves: POM
Heat exchanger: plates: stainless steel 1.4401,POM,plates + connecting pieces: stainless steel,coating (optional): based on silica,copper brazing,brazing: Cu or StS
Design data (Friwa)
Cold water inlet temperature: 10 °C
Field of application:
Domestic hot water preparation operating on the principle of a flow-type water heater

Application range:
In solar thermal systems and photovoltaic heating systems
In systems with a heat pump, a solid fuel boiler, oil or gas boiler
Connection to a buffer tank
as a quadruple cascade up to 240 l/min
No domestic hot water tank necessary
The energy required to heat the water is taken from the buffer tank

Operating data:
Max. operating pressure: primary = 6 bar, secondary = 10 bar
Max. operating temperature: 90 °C
Min. flow rate: 2 l/min
Max. flow rate: 60 l/min

The CE-conformity of the module has been certified according to DIN EN 60335 and SVGW.