• Best quality
  • Quick assembly
  • Longevity

Friwa

DHW

technology

FriwaMidi up to 50 l/min, FC3.10

Domestic hot water preparation operating on the principle of a flow-type water heater

Withdrawal capacity: 2-50 l/min
Circulation: optional

SKU
64055XX
Prices are only visible for registered users.

Our offer is exclusively aimed at corporate clients.

Operating data
Max. operating temperature: 95 °C
Max. operating pressure primary: 3 bar
Max. operating pressure secondary: 10 bar
Kvs value primary: 4,5
Kvs value secondary: 3,9
Max. flow rate: 50 l/min
Transmission performance: 129 kW
Min. flow rate: 2 l/min
Equipment
Controller: FC3.10
Check valves: primary: 2 x 190 mm wc
Shut-off valves: Ball valves and piston valves
Sensors: primary: 1 x Pt1000 / secondary: 2 x Pt1000 / 1 x flow meter
Heat exchanger: 40 plates, copper solder/coated
Temperature sensor: primär: 1 x Pt1000; sekundär: 2 x Pt1000
Circulation: optional
Flow meter: 1-130 l/min
Opening pressure check valve: 190 mm wc
Dimensions
Height: 795 mm
Width: 602 mm
Nominal diameter: DN 20 (¾")
Depth: 298 mm
Installation length: 757 mm
Connection primary: 1½" ext. thread
Connection secondary: 1" ext. thread
Centre distance primary: 120 mm
Centre distance secondary: 100 mm
Materials
Valves and fittings: Brass
Gaskets: EPDM / AFM34
Insulation: EPP
Piping: Stainless steel
Check valves: Brass
Heat exchanger: Solder: copper,Plates + connecting pieces: stainless steel,coating (optional): based on silica
Design data (Friwa)
Cold water inlet temperature: 10 °C
Withdrawal capacity: min. flow rate: 2 l/min
Field of application:
Domestic hot water preparation operating on the principle of a flow-type water heater

Application range:
In solar thermal systems
In systems with a heat pump, a solid fuel boiler, oil or gas boiler
Connection to a buffer tank
As a quadruple cascade up to 200 l/min (as per SPF LK 1)*
No domestic hot water tank necessary
Energy for heating the water is taken from the buffer tank
Operating data:
Max. operating pressure: primary = 3 bars, secondary = 10 bars
Max. operating temperature: 95 °C
Min. flow rate: 2 l/min
Max. flow rate: 50 l/min

The CE-conformity of the module has been certified according to DIN EN 60335 and SVGW.

*Indication of performance as per SPF test procedure

Do you have any questions?

If you have any questions about our products and services, please contact us via telephone or via e-mail. You can also use the contact form to submit your request.

Image