Domestic hot water preparation operating on the principle of a flow-type water heater
Withdrawal capacity: 2-28 l/min
Circulation: no

SKU
64015
Prices are only visible for registered users.

Our offer is exclusively aimed at corporate clients.

More Information
Opening pressure check valve 200 mm wc
Operating data
Max. operating temperature: 95 °C
Max. operating pressure primary: 3 bar
Max. operating pressure secondary: 10 bar
Kvs value primary: 3,1
Kvs value secondary: 2,4
Max. flow rate: 28 l/min
Transmission performance: 69 kW
Min. flow rate: 2 l/min
Note: The CE-conformity of the module has been certified according to DIN EN 60335 and SVGW.
Equipment
Controller: FC3.10
Check valves: primary: 1 x 200 mm wc
Shut-off valves: Ball valves and piston valves
Sensors: 2 x Pt1000
Heat exchanger: E8ASW-N, 32 plates
Temperature sensor: 2x Pt1000
Flow rate sensor: Type VFS 20-40 l/min
Circulation: optional
Flow meter: Measuring range: 2 - 40 l/min
Dimensions
Height: 539 mm
Width: 309 mm
Nominal diameter: DN 15 (½")
Depth: 314 mm
Installation length: 494 mm
Connection primary: ¾" int. thread
Connection secondary: ¾" ext. thread
Connection circulation line: 1" ext. thread
Centre distance primary: 90 mm
Centre distance secondary: 90 mm
Materials
Valves and fittings: Brass
Gaskets: EPDM / AFM34
Insulation: EPP
Piping: Stainless steel
Check valves: Brass
Heat exchanger: Solder: copper,Plates + connecting pieces: stainless steel,coating (optional): based on silica
Design data (Friwa)
Cold water inlet temperature: 10 °C
Set hot water temperature: 45 °C,60 °C
Withdrawal capacity Friwa: Withdrawal of hot water with 45 °C at the preset hot water temperature
Withdrawal capacity: min. flow rate: 2 l/min
necessary primary flow temperature 1: 60 °C
necessary primary flow temperature 2: 70 °C
Field of application:
Domestic hot water preparation operating on the principle of a flow-type water heater

Application range:
In solar thermal systems
In systems with solid fuel boilers, oil or gas boilers
Connection to a buffer tank
No domestic hot water tank necessary
Energy for heating the water is taken from the buffer tank

Operating data:
Max. operating pressure: primary = 3 bars, secondary = 10 bars
Max. operating temperature: 95 °C
Min. flow rate: 2 l/min
Max. flow rate: 28 l/min
The CE-conformity of the module has been certified according to
DIN EN 60335 and SVGW.


*Indication of performance as per SPF test procedure