Search results for: '120 230'
-
PAW Constant temperature controller PKR6Item number : 703601
Easy assembly and disassembly thanks to the smart PAW snap-in mechanism,
with 2 m cable and safety plug,
incl. mounting set for snap-in assembly on the PAW mixing valve and Pt1000 screw-in sensor G¼" for the flow ball valve,
change-over switch for manual / automatic operation
controller settings for direction of rotation, operation mode and nominal temperature can be adjusted at the display
Technical data
Power supply: 230 V - 50 Hz
Power consumption: 3 W
Torque: min. 6 Nm
Setting time 90°: 120 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Solar check valve RSS DN 20with brass valve plate,
all installation positions possible,
opening pressure 200 mm wc,
¾" internal thread,
length = 50 mm
1211: can be opened, up to 150 °C
12111: without possibility for manual opening, up to 220 °C Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with actuator - DN 20 (¾")Return flow temperature maintenance - DN 20 (¾")
with actuator
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
2-way zone valve DN 20for connecting and disconnecting single storage tanks,
DN 20, ¾" int. thread,
setting time for 90°: 30 sec. Learn MoreOur offer is exclusively aimed at corporate clients.
-
System separation DN 25 (1") for HeatBloC®sFunction:
Separation of the boiler circuit and the consumer circuit
Field of application:
for radiant panel heating systems with plastic pipes for the protection of new boilers in older heating installations
Recommended application range:
Min. residual head: 1.5 m
Temperature difference primary: 60-50 °C
Temperature difference secondary: 35-45 °C
Range of performance:
depending on the pump of the heating circuit used and the amount of plates of the heat exchanger
16 plates: up to 20 kW, 10 K up to 1720 l/h
30 plates: up to 23 kW, 10 K up to 2010 l/h
40 plates: up to 25 kW, 10 K up to 2150 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
Set extension pieces DN 20 - DN 25Set of adaptor pieces for the overhead installation of HeatBloC®s DN 25 below distribution manifolds DN 20,
centre distance changed from 90 mm to 125 mm, connections 1" nut x 1" flange (for nut 1½") flat sealing.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Stainless-steel corrugated hose SolarflexIdeal for the roof part leading to the collector. Learn More
Our offer is exclusively aimed at corporate clients.
-
Fitting for heat flowmeter DN 20- for HeatBloC®s DN 20
- for heat flowmeters with the dimensions ¾" external thread x 110 mm
- to be mounted above the insulation
Scope of delivery:
- Thermo ball valve
- Screw-in fittings
- Union nuts
- Adapter pipe
- Flange fitting
- T-piece with counter nut and immersion sleeve
- Seals
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Reducer set DN 25 - DN 20for installation of HeatBloC®s DN 20 on modular distribution manifolds DN 25,
adapter set 1½" external thread, flat-sealing with nut on ¾" PAW flange,
reduction of the centre distance from 125 mm to 90 mm,
distance pipe 1" internal thread x 1" external thread, flat sealing, brass, with sealing.
The required union nuts 1" internal thread are part of the scope of delivery of the HeatBloC®s.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
SBMCheck valve, can be opened, with seal
for warm water central heating PN 10, 120 °C,
suited for horizontal and vertical installation,
to be screwed directly to the pump.
Opening pressure 200 mm wc Learn MoreOur offer is exclusively aimed at corporate clients.