Search results for: 'CONTROLLER'
- Related search terms
- controllers sc3.10
- controller sc3.10
-
Controller Alpha BasisConnection unit for single room controls of heating and cooling systems in combination with surface temperature regulation.
The power supply of the components is provided directly via the controller; minimised wiring effort.
Controller Alpha Basis STD Plus: Designated for the connection of up to 6 room operating units and up to 15 actuators with 230 V~ operating voltage.
Controller Alpha Basis Comfort: Designated for the connection of up to 10 room operating units and up to 18 actuators with 230 V~ operating voltage.
Features:
• Signal input for temperature limitation or dew point sensor
• Connection for an external time switch
• Change Over connection for switching between heating and cooling
• Controller Alpha Basis STD Plus: control of the pump
• Controller Alpha Basis Comfort: extended control of boiler and pump, after-run time adjustable
• Direction of operation of the actuators "zero current closed" (NC); without pump control, also "zero current open" (NO) possible
Scope of delivery:
Wall bracket with mounting rail for an easy and direct installation in the wall-mounted or flush-mounted cupboard Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW Weather compensated controller PWR6Same type as the PAW constant temperature controller PKR6 (art.no. 703601), but for the use of a weather-compensated heating circuit.
The package includes the outdoor sensor, the flow sensor as well as the source sensor. This ensures that the mixing valve or the heating circuit can be operated in an autarkic manner and without boiler control.
In addition, it is possible to set the room temperature centrally in the flat via a room based remote control (art.no. 1359501). Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW Constant temperature controller PKR6Item number : 703601
Easy assembly and disassembly thanks to the smart PAW snap-in mechanism,
with 2 m cable and safety plug,
incl. mounting set for snap-in assembly on the PAW mixing valve and Pt1000 screw-in sensor G¼" for the flow ball valve,
change-over switch for manual / automatic operation
controller settings for direction of rotation, operation mode and nominal temperature can be adjusted at the display
Technical data
Power supply: 230 V - 50 Hz
Power consumption: 3 W
Torque: min. 6 Nm
Setting time 90°: 120 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Thermoelectric actuator NC, 230 VThermoelectric actuator NC, 230 V
1288601101: with connecting adapter for IMI valves or Frese differential pressure controller.
1288601102: with connecting adapter for PAW floor distribution manifold valves.
1288601103: with connecting adapter for PAW injection-type circuit.
The actuator is controlled by a 230 V standard room temperature controller with a 2-point output or a pulse width modulation. Learn MoreOur offer is exclusively aimed at corporate clients.
-
MB3.10Communication module to integrate PAW systems with domestic hot water controllers FC3.10 into superior systems with Modbus RTU interface.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
WiFi3.10For visualising the system parameters with FC3.10 controllers on a server
- Optional accessory for FC3.10
Availability: on request
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Connection set for MComMains cable (24 V DC, RJ12, RS485) for the connection of the MCom controllers to the power supply.
Please note: For the function of a MC system with up to 8 controllers, one connection set is necessary.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Extension set MCom DN 25 (1") (unmixed)Autarkic controller for an automatic, dynamic balancing of the distribution manifold through an electronic regulation of the differential pressure, 0-600 mbars
Display of the flow rate values of the pump (Grundfos) Modbus for an optional integration in a smart home system with an external nominal value indication
Components:
- Controller MCom 3.4
- Differential pressure sensor DPS 0 - 0.6 bars
- 2x Temperature sensor Pt1000
- Pump
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Extension set MCom DN 25 (1") (mixed)Field of application:
Suitable for mixed PAW heating circuits as of 2017!
Extension of a HeatBloC® MC for the automatic, hydraulic balancing of the distribution manifold
Components:
- Controller MCom 3.4
- Differential pressure sensor DPS 0 - 0.6 bars
- 2x Temperature sensor Pt1000
- Actuator SR10 (24 Vdc)
- Pump
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Extension set MCom DN 32Field of application:
Suitable for mixed PAW heating circuits as of 2017!
Extension of a HeatBloC® MC for the automatic, hydraulic balancing of the distribution manifold
Components:
- Controller MCom 3.4
- Differential pressure sensor DPS 0 - 0.6 bars
- 2x Temperature sensor Pt1000
- Actuator SR10 (24 Vdc)
- Pump
Learn MoreOur offer is exclusively aimed at corporate clients.