SolarBloC® midi BasicApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 60 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 40 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® maxi BasicApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 125 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 80 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW Weather compensated controller PWR6Same type as the PAW constant temperature controller PKR6 (art.no. 703601), but for the use of a weather-compensated heating circuit.
The package includes the outdoor sensor, the flow sensor as well as the source sensor. This ensures that the mixing valve or the heating circuit can be operated in an autarkic manner and without boiler control.
In addition, it is possible to set the room temperature centrally in the flat via a room based remote control (art.no. 1359501). Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolexMaxi TW up to 100 m²Field of application: for charging buffer storage tanks
Application range: up to 100 m² collector surface with heat quantity measurement according to the BAFA promotion directive for solar thermal systems
The CE-conformity of the installation has been certified according to DIN EN 60335. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® midi Basic, 3-lineApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 60 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 40 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
HomeBloC® Basic WFfor properties with one or various radiant floor circuits
Wall-mounted or flush-mounted cupboard must be ordered separately. Learn MoreOur offer is exclusively aimed at corporate clients.
-
HomeBloC® Basic WRfor properties with one or various radiator circuits
Wall-mounted or flush-mounted cupboard must be ordered separately. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® midi Basic return stationApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 60 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 40 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
SolarBloC® maxi Basic return stationApplication range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 125 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 80 m² collector surface
Please note: In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check. Learn MoreOur offer is exclusively aimed at corporate clients.
-
Controller Alpha BasisConnection unit for single room controls of heating and cooling systems in combination with surface temperature regulation.
The power supply of the components is provided directly via the controller; minimised wiring effort.
Controller Alpha Basis STD Plus: Designated for the connection of up to 6 room operating units and up to 15 actuators with 230 V~ operating voltage.
Controller Alpha Basis Comfort: Designated for the connection of up to 10 room operating units and up to 18 actuators with 230 V~ operating voltage.
Features:
• Signal input for temperature limitation or dew point sensor
• Connection for an external time switch
• Change Over connection for switching between heating and cooling
• Controller Alpha Basis STD Plus: control of the pump
• Controller Alpha Basis Comfort: extended control of boiler and pump, after-run time adjustable
• Direction of operation of the actuators "zero current closed" (NC); without pump control, also "zero current open" (NO) possible
Scope of delivery:
Wall bracket with mounting rail for an easy and direct installation in the wall-mounted or flush-mounted cupboard Learn MoreOur offer is exclusively aimed at corporate clients.