Conversion kit for changing the flowThe conversion kit for changing the flow line is mandatory for mixing valves K33 with bypass at the front.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Conversion kit from K31 to K32 DN 25-401x return pipe with check valve (200 mm wc, can be opened)
1x 3-way mixing valve
1x union nut
1x gasket
1x actuator with stop bolt and rotation lock
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Conversion kit for changing the flow line to flow on the right for K33/34Before: mixing valve K33 (with bypass on the front), DN 25, flow left
After: mixing valve K33 (with bypass on the front), DN 25, flow on the right
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Conversion kit for changing the flow line to flow on the left for K33/34Before: mixing valve K33 (with bypass on the front), DN 25, flow on the right
mixing valve K34 (with bypass on the front), DN 25, flow on the right + flow on the left
After: mixing valve K33 (with bypass on the front), DN 25, flow on the left
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Reducer set DN 50 - DN 322 reducer flanges made of steel, galvanized/brass for the assembly of a HeatBloC® DN 32 on a modular distribution manifold DN 50.
One side flange DN 50 - PN 6, other side flange DN 32 - 1¼".
Reduction of the centre distance from 180 mm to 125 mm.
With gaskets and screws for connection to DN 50, installation height = 48 mm
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Reducer set DN 50 - DN 402 reducing flanges made of zinced steel for connecting a DN 40 HeatBloC® on a DN 50 modular distribution manifold. For the assembly of a DN 40 pump, installation length 250 mm, in a DN 50 HeatBloC®.
One side DN 50 flange (PN 6), other side DN 40 flange (PN 6). Reduction of the centre distance from 180 mm to 160 mm, with seals and screws, installation height = 13 mm
Use only with slip-on flanges!
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Floor distribution manifoldThe PAW heating distribution manifold for radiant floor heating ensures a steady and comfortable heat distribution in the flat. Filling, draining and venting is easily possible. The heating distribution manifold can be mounted in a flush-mounted or a wall-mounted cabinet.
The floor distribution manifold is available from a 2-fold version up to a 8-fold version.
For the versions WF and WRF, the injection circuit is mandatory.
Connections: ¾" ext. thread Eurocone
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 50 (2")direct / unmixed
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 250 kW; 20 K up to 10800 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Reducer set DN 40 - DN 32Reducer flanges made of brass for the assembly of a pump DN 32* in HeatBloC®s DN 40 or for connection of a single HeatBloC® DN 32 on a distribution manifold DN 40.
One side flange DN 40 - PN 6, other side flange for 2" union nut, flat sealing.
Reduction of the centre distance from 160 mm to 125 mm, installation height = 35 mm.
*For the installation of a DN 32 pump 2x nut and seals are required additionally (2x N00121).
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K36E DN 25 (1")Boiler charging set with integrated overflow valve
Field of application: Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 40 kW; 20 K up to 1725 l/h
360343x: Opening temperature 45 °C
360373x: Opening temperature 60 °C
Learn MoreOur offer is exclusively aimed at corporate clients.