HeatBloC® K35 DN 25 (1")3-temperatures mixing valve
Field of application: Heating installations with buffer tank and solar heating support, control of radiant floor and panel heating systems
Recommended application range: up to 32.5 kW; 20 K up to 1400 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K36E DN 25 (1")Boiler charging set with integrated overflow valve
Field of application: Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 40 kW; 20 K up to 1725 l/h
360343x: Opening temperature 45 °C
360373x: Opening temperature 60 °C
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K36 DN 20 (¾")Boiler charging set with thermal control valve
Field of application: Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 10 kW; 10 K up to 860 l/h
Opening temperature 45 °C (item no. 320353xx)
Opening temperature 60 °C (item no. 320363xx)
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33R DN 25 (1")Constant value control circuit, electronic
Field of application: for thermally controlled radiant heating, for low-temperature heating used as a return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range:
up to 22.5 kW*; (radiant heating, Delta T = 10 K)
up to 45 kW* (return flow temperature maintenance, Delta T = 20 K),
10 / 20 K up to 1940 l/h ↲ Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33R DN 32 (1¼")Constant value control circuit, electronical
Field of application: for thermally controlled radiant heating, for low-temperature heating used as a return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 32 kW; (radiant heating, Delta T = 10 K)
up to 64 kW (return flow temperature maintenance, Delta T = 20 K), 10 / 20 K up to 2760 l/h ↲
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Reducer set DN 25 - DN 20for installation of HeatBloC®s DN 20 on modular distribution manifolds DN 25,
adapter set 1½" external thread, flat-sealing with nut on ¾" PAW flange,
reduction of the centre distance from 125 mm to 90 mm,
distance pipe 1" internal thread x 1" external thread, flat sealing, brass, with sealing.
The required union nuts 1" internal thread are part of the scope of delivery of the HeatBloC®s.