Hydraulic separator DN 20 (¾")Hydraulic separators are used when there are simultaneously one or more heat generator circuits/primary circuits with an own pump and one or more consumer/secondary circuits with a distribution pump in an installation.
The hydraulic separator causes a hydraulic separation of the connected circuits.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
SBE - ext. thread DN 25Check valve, can be opened,
with external thread and PAW flange
for warm water central heating PN 10, 120 °C.
Suited for horizontal and vertical installation.
Can also be used as non return valve.
To be directly screwed to the pump.
Opening pressure 200 mm wc Learn MoreOur offer is exclusively aimed at corporate clients.
-
SBE - int. threadCheck valve, can be opened,
with internal thread and PAW flange
for warm water central heating PN 10, 120 °C.
Suited for horizontal and vertical installation,
Can also be used as non return valve.
To be directly screwed to the pump.
Opening pressure 200 mm wc Learn MoreOur offer is exclusively aimed at corporate clients.
-
SBE - ext. thread with automatic air passage DN 25Check valve, can be opened,
with automatic air passage,
with external thread and PAW flange
for warm water central heating PN 10, 120 °C.
Suited for horizontal and vertical installation.
Can also be used as non return valve.
To be directly screwed to the pump.
Opening pressure 200 mm wc Learn MoreOur offer is exclusively aimed at corporate clients.
-
SBE - int. thread with automatic air passageCheck valve, can be opened, with automatic air passage, with internal thread and PAW flange
for warm water central heating PN 10, 120 °C.
Suited for horizontal and vertical installation.
Can also be used as non return valve.
To be directly screwed to the pump.
Opening pressure 200 mm wc Learn MoreOur offer is exclusively aimed at corporate clients.
-
Reducer set DN 50 - DN 402 reducing flanges made of zinced steel for connecting a DN 40 HeatBloC® on a DN 50 modular distribution manifold. For the assembly of a DN 40 pump, installation length 250 mm, in a DN 50 HeatBloC®.
One side DN 50 flange (PN 6), other side DN 40 flange (PN 6). Reduction of the centre distance from 180 mm to 160 mm, with seals and screws, installation height = 13 mm
Use only with slip-on flanges!
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW Weather compensated controller PWR6Same type as the PAW constant temperature controller PKR6 (art.no. 703601), but for the use of a weather-compensated heating circuit.
The package includes the outdoor sensor, the flow sensor as well as the source sensor. This ensures that the mixing valve or the heating circuit can be operated in an autarkic manner and without boiler control.
In addition, it is possible to set the room temperature centrally in the flat via a room based remote control (art.no. 1359501). Learn MoreOur offer is exclusively aimed at corporate clients.
-
3-way zone valve DN 20for switching between single storage tanks,
DN 20, ¾" int. thread,
setting time for 90°: 18 sec.,
Kvs value = 7 Learn MoreOur offer is exclusively aimed at corporate clients.
-
2-way zone valve DN 20for connecting and disconnecting single storage tanks,
DN 20, ¾" int. thread,
setting time for 90°: 30 sec. Learn MoreOur offer is exclusively aimed at corporate clients.