Hydraulic separator DN 32 (1¼")Hydraulic separators are used when there are simultaneously one or more heat generator circuits/primary circuits with an own pump and one or more consumer/secondary circuits with a distribution pump in an installation.
The hydraulic separator causes a hydraulic separation of the connected circuits.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Extension set for low-loss header DN 32for a subsequent conversion into a distribution manifold with integrated hydraulic separator (low-loss header).
Range of application up to 2600 l/h, max. up to a 3-fold distribution manifold MV3.
Consisting of two distance rings for a resistance-free connection of flow and return chamber, incl. screws and o-rings.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Connection flange DN 25- with check valve, can be opened manually, automatic air passage
- with connection for automatic air vent (½" sleeve)
Opening pressure 200 mm wc Learn MoreOur offer is exclusively aimed at corporate clients.
-
Conversion kit from K31 to K32 DN 25-401x return pipe with check valve (200 mm wc, can be opened)
1x 3-way mixing valve
1x union nut
1x gasket
1x actuator with stop bolt and rotation lock
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Brass pipes for return1 x Brass pipe with check valve (200 mm wc, can be opened) for the return
2 x seal (EPDM)
Learn MoreOur offer is exclusively aimed at corporate clients.
-
SBMCheck valve, can be opened, with seal
for warm water central heating PN 10, 120 °C,
suited for horizontal and vertical installation,
to be screwed directly to the pump.
Opening pressure 200 mm wc Learn MoreOur offer is exclusively aimed at corporate clients.
-
SBM with automatic air passageCheck valve, can be opened, with seal
for warm water central heating PN 10, 120 °C,
suited for horizontal and vertical installation,
to be screwed directly to the pump.
Opening pressure 200 mm wc Learn MoreOur offer is exclusively aimed at corporate clients.
-
Extension set for low-loss header DN 25For a subsequent conversion into a distribution manifold with integrated hydraulic separator (low-loss header).
Range of application up to 1600 l/h, max. up to a 3-fold distribution manifold MV3.
Consisting of two distance rings for a resistance-free connection of flow and return chamber, incl. screws and o-rings.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Solar check valve RSS DN 20with brass valve plate,
all installation positions possible,
opening pressure 200 mm wc,
¾" internal thread,
length = 50 mm
1211: can be opened, up to 150 °C
12111: without possibility for manual opening, up to 220 °C Learn MoreOur offer is exclusively aimed at corporate clients.