Hydraulic separator DN 20 (¾")Hydraulic separators are used when there are simultaneously one or more heat generator circuits/primary circuits with an own pump and one or more consumer/secondary circuits with a distribution pump in an installation.
The hydraulic separator causes a hydraulic separation of the connected circuits.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Hydraulic separator DN 25 (1")Hydraulic separators are used when there are simultaneously one or more heat generator circuits/primary circuits with an own pump and one or more consumer/secondary circuits with a distribution pump in an installation.
The hydraulic separator causes a hydraulic separation of the connected circuits.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Hydraulic separator DN 32 (1¼")Hydraulic separators are used when there are simultaneously one or more heat generator circuits/primary circuits with an own pump and one or more consumer/secondary circuits with a distribution pump in an installation.
The hydraulic separator causes a hydraulic separation of the connected circuits.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Actuator PS5-230-2PThe servomotor is characterised by its robust construction and quiet operation. The direction of rotation, activation of an additional switch and manual interventions are indicated by LED lights. Learn MoreOur offer is exclusively aimed at corporate clients.
-
Thermax - DN 20Field of application: for wall-mounted boilers
Recommended application range:
K31: up to 23 kW; 20 K up to 1000 l/h
K32: up to 19 kW; 20 K up to 820 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
System separation DN 25 (1") for HeatBloC®sFunction:
Separation of the boiler circuit and the consumer circuit
Field of application:
for radiant panel heating systems with plastic pipes for the protection of new boilers in older heating installations
Recommended application range:
Min. residual head: 1.5 m
Temperature difference primary: 60-50 °C
Temperature difference secondary: 35-45 °C
Range of performance:
depending on the pump of the heating circuit used and the amount of plates of the heat exchanger
16 plates: up to 20 kW, 10 K up to 1720 l/h
30 plates: up to 23 kW, 10 K up to 2010 l/h
40 plates: up to 25 kW, 10 K up to 2150 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW Constant temperature controller PKR6Item number : 703601
Easy assembly and disassembly thanks to the smart PAW snap-in mechanism,
with 2 m cable and safety plug,
incl. mounting set for snap-in assembly on the PAW mixing valve and Pt1000 screw-in sensor G¼" for the flow ball valve,
change-over switch for manual / automatic operation
controller settings for direction of rotation, operation mode and nominal temperature can be adjusted at the colour display.
Technical data
Power supply: 230 V - 50 Hz
Power consumption: 3 W
Torque: min. 6 Nm
Setting time 90°: 120 s
Control range: 10-90°C (adjustable) Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW Weather compensated controller PWR6Same type as the PAW constant temperature controller PKR6 (art.no. 703601), but for the use of a weather-compensated heating circuit.
The package includes the outdoor sensor, the flow sensor as well as the source sensor. This ensures that the mixing valve or the heating circuit can be operated in an autarkic manner and without boiler control.
In addition, it is possible to set the room temperature centrally in the flat via a room based remote control (art.no. 1359501). Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with actuator - DN 20 (¾")Return flow temperature maintenance - DN 20 (¾")
with actuator
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Return flow temperature maintenance with actuator - DN 25 (1")Return flow temperature maintenance - DN 25 (1")
with actuator
Field of application: for heating systems with return flow temperature maintenance
for solid fuel boilers, wood-fired and stove heating systems
Learn MoreOur offer is exclusively aimed at corporate clients.