PAW actuator SR2easy assembly and disassembly thanks to the smart PAW snap-in mechanism,
with 1.5 m cable and mounting set for snap-in assembly on the PAW mixing valve,
for weather-compensated control,
due to the removable scale it is suited for the flow on the right or left side
change-over switch for manual / automatic operation
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW actuator SR5Change-over switch for manual / automatic operation,
easy assembly and disassembly thanks to the smart PAW snap-in mechanism,
with 1.5 m cable and mounting set for snap-in assembly on the PAW mixing valve,
for weather-compensated control,
due to the removable scale it is suited for the flow on the right or left side
Technical data
Electrical connection: 230 V / 50 Hz
Input power: 2.5 W
Torque: 5 Nm
Setting time for 90°: 140 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW actuator SR10due to the removable scale it is suited for flow on the right or left side,
easy assembly and disassembly thanks to the smart PAW snap-in mechanism,
with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve,
for weather-compensated control, change-over switch for manual / automatic operation
Technical data
Electrical connection: 230 V / 50 Hz
Input power: 3.5 W
Torque: 10 Nm
Setting time for 90°: 140 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW Weather compensated controller PWR6Same type as the PAW constant temperature controller PKR6 (art.no. 703601), but for the use of a weather-compensated heating circuit.
The package includes the outdoor sensor, the flow sensor as well as the source sensor. This ensures that the mixing valve or the heating circuit can be operated in an autarkic manner and without boiler control.
In addition, it is possible to set the room temperature centrally in the flat via a room based remote control (art.no. 1359501). Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW Constant temperature controller PKR6Item number : 703601
Easy assembly and disassembly thanks to the smart PAW snap-in mechanism,
with 2 m cable and safety plug,
incl. mounting set for snap-in assembly on the PAW mixing valve and Pt1000 screw-in sensor G¼" for the flow ball valve,
change-over switch for manual / automatic operation
controller settings for direction of rotation, operation mode and nominal temperature can be adjusted at the display
Technical data
Power supply: 230 V - 50 Hz
Power consumption: 3 W
Torque: min. 6 Nm
Setting time 90°: 120 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW actuator SR10 for DN 40due to the removable scale it is suited for flow on the right or left side, easy assembly and disassembly thanks to the smart PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, change-over switch for manual / automatic operation
Technical data
Electrical connection: 230 V / 50 Hz
Input power: 3.5 W
Torque: 10 Nm
Setting time for 90°: 140 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
PAW actuator SR10 for DN 50due to the removable scale it is suited for flow on the right or left side, easy assembly and disassembly thanks to the smart PAW snap-in mechanism, with 1.5 m cable and mounting set for halting assembly on the PAW mixing valve, for weather-compensated control, change-over switch for manual / automatic operation
Technical data
Electrical connection: 230 V / 50 Hz
Input power: 3.5 W
Torque: 10 Nm
Setting time for 90°: 140 s
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Thermoelectric actuator NC, 230 VThermoelectric actuator NC, 230 V
1288601101: with connecting adapter for IMI valves or Frese differential pressure controller.
1288601102: with connecting adapter for PAW floor distribution manifold valves.
1288601103: with connecting adapter for PAW injection-type circuit.
The actuator is controlled by a 230 V standard room temperature controller with a 2-point output or a pulse width modulation. Learn MoreOur offer is exclusively aimed at corporate clients.
-
MB3.10Communication module to integrate PAW systems with domestic hot water controllers FC3.10 into superior systems with Modbus RTU interface.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K36 DN 20 (¾")Boiler charging set with thermal control valve
Field of application: Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 10 kW; 10 K up to 860 l/h
Opening temperature 45 °C (item no. 320353xx)
Opening temperature 60 °C (item no. 320363xx)
Learn MoreOur offer is exclusively aimed at corporate clients.