Conversion kit for changing the flowThe conversion kit for changing the flow line is mandatory for mixing valves K33 with bypass at the front.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K32 DN 50 (2")3-way mixing valve
Field of application: for heating systems controlled by a mixing valve
Recommended application range: up to 230 kW; 20 K up to 9980 l/h
Flow and return line can be changed on site, the mixing valve can be easily adapted.
The HeatBloC® can be delivered with flow on the left against additional charge.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K32 DN 40 (1½")3-way mixing valve
Field of application: for heating systems controlled by a mixing valve
Recommended application range: up to 125 kW; 20 K up to 5400 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K35 DN 25 (1")3-temperatures mixing valve
Field of application: Heating installations with buffer tank and solar heating support, control of radiant floor and panel heating systems
Recommended application range: up to 32.5 kW; 20 K up to 1400 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
Set extension pieces DN 20 - DN 25Set of adaptor pieces for the overhead installation of HeatBloC®s DN 25 below distribution manifolds DN 20,
centre distance changed from 90 mm to 125 mm, connections 1" nut x 1" flange (for nut 1½") flat sealing.
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 50 (2")direct / unmixed
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 250 kW; 20 K up to 10800 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K31 DN 40 (1½")direct / unmixed
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 150 kW; 20 K up to 6500 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33R DN 25 (1")Constant value control circuit, electronic
Field of application: for thermally controlled radiant heating, for low-temperature heating used as a return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range:
up to 22.5 kW*; (radiant heating, Delta T = 10 K)
up to 45 kW* (return flow temperature maintenance, Delta T = 20 K),
10 / 20 K up to 1940 l/h ↲ Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® K33R DN 32 (1¼")Constant value control circuit, electronical
Field of application: for thermally controlled radiant heating, for low-temperature heating used as a return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 32 kW; (radiant heating, Delta T = 10 K)
up to 64 kW (return flow temperature maintenance, Delta T = 20 K), 10 / 20 K up to 2760 l/h ↲
Learn MoreOur offer is exclusively aimed at corporate clients.