PAW Weather compensated controller PWR6Same type as the PAW constant temperature controller PKR6 (art.no. 703601), but for the use of a weather-compensated heating circuit.
The package includes the outdoor sensor, the flow sensor as well as the source sensor. This ensures that the mixing valve or the heating circuit can be operated in an autarkic manner and without boiler control.
In addition, it is possible to set the room temperature centrally in the flat via a room based remote control (art.no. 1359501). Learn MoreOur offer is exclusively aimed at corporate clients.
-
Overflow setOverflow valve with scale, bypass pipe, elbow gland, completely self-sealing.
Centre distance A = length, see table
For larger distances, a copper pipe 22 in the necessary length must be installed on site.
2850 and 2851: with screw connection 2 x ½" external thread
2853: with screw connection 2 x ¾", flat-sealing, suitable for foreign products Learn MoreOur offer is exclusively aimed at corporate clients.
-
Overflow set for HeatBloC®s DN 20with self-sealing counter-T-pieces and elbow gland, adjustment range 1-6 m wc, suitable for HeatBloC®
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® MC41 - DN 25 (1")direct / unmixed
with integrated controller
Application range: for boiler charging, for modulating temperature heating
Recommended application range: up to 50 kW; 20 K up to 2150 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® MC42 - DN 25 (1")3-way mixing valve
with integrated controller
Application range: for heating systems controlled by a mixing valve
Recommended application range: up to 40 kW; 20 K up to 1750 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® MC43 - DN 25 (1")Constant value control circuit, electronic
with integrated controller
Application range: for low-temperature heating systems controlled by a mixing valve, constant value control circuit or indication of the nominal temperature via Smart Home environment
Recommended application range: up to 45.5 kW; 20 K up to 1940 l/h↲ Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® MC44 - DN 25 (1")3-way mixing valve with integrated bypass 0-50 %
with integrated controller
Application range: for low-temperature heating systems controlled by a mixing valve
Recommended application range:up to 45.5 kW; 20 K up to 1940 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® MC45 - DN 25 (1")3-temperatures mixing valve
with integrated controller
Application range:
Heating installations with buffer tank and solar heating support, control of radiant floor and panel heating systems
Recommended application range: up to 32.5 kW; 20 K up to 1400 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® MC41 - DN 32 (1¼")direct / unmixed
with integrated controller
Field of application: for boiler charging, for modulating temperature heating
Recommended application range: up to 65 kW; 20 K up to 2800 l/h Learn MoreOur offer is exclusively aimed at corporate clients.
-
HeatBloC® MC42 - DN 32 (1¼")3-way mixing valve
with integrated controller
Application range: for heating systems controlled by a mixing valve
Recommended application range: up to 51 kW; 20 K up to 2200 l/h
Learn MoreOur offer is exclusively aimed at corporate clients.